Design of Shear Connectors in Composite Bridge Beams
A new approach is described for the design of stud shear connectors, in composite steel and concrete beams that are subjected to vehicular loads, which allows for the interaction between...

Design of Composite Slabs for Vertical Shear
Three major modes of failure should be considered in the design of the positive moment regions of composite slabs incorporating profiled steel sheeting, viz.: flexure, longitudinal slip...

Investigation of Corners and Joints Applied to a Steel-Concrete Composite Caisson
We have developed a caisson composed of steel-concrete composite slabs and steel structures, which we call a `Hybrid Caisson.' We studied the structural principles and usability of the...

Development of Composite Slab with Truss-Typed Shear Connectors
This paper describes the results of the test on a steel-concrete composite slab with truss-typed shear connectors. This composite slab was recently developed. A series of tests were conducted...

Composite Columns Subjected to Bending and Shear
This paper describes experimental as well as analytical studies of the post elastic deformation and fracture behaviors of wide flange steel encased reinforced concrete (SRC) composite...

Connection of Beam Flange to Concrete-Filled Tubular Column
Research has been carried out on a frame composed of a concrete-filled steel tubular column and H-shaped steel beam with the aim of developing a reasonable connection method. The proposed...

Steel Beams with Reinforced Concrete Stiffened Ends
For the construction of office building with long span beams, steel beams with reinforced concrete stiffened ends are being used in order to increase the stiffness. This paper describes...

Thin Walled Circular Concrete Filled Steel Tubular Columns
The thin walled steel tube filled with high strength concrete delivers the economies of a concrete column with the speed of construction and the constructability of a steel column resulting...

Strength and Stiffness Behavior of Composite Steel Grid Decks
This paper briefly discusses the historical development of composite steel grid decks. The static and fatigue behavior under bending of filled and unfilled steel grid decks (exodermic)...

Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...

Perfobond Rib Connectors for Composite Beams
In this paper, the influence of concrete strength, transverse reinforcement and concrete dowels on the capacity of perfobond rib shear connectors is examined. Perfobond rib connector is...

Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...

The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...

Ovality in Pipe Rehabilitation Design
Pipes in need of structural rehabilitation often have longitudinal cracks (at the crown and elsewhere) and exhibit significant ovality (5-10%). When these pipes are lined with current...

Townsite Lateral-Stage 2 Belle Fourche Unit - Cheyenne Division Concrete: Pipe with Dumped Bedding and Embedment
In 1933, M. G. Spangler presented three bedding configurations and the concept of a bedding factor to relate the supporting strength of buried concrete pipe to the strength obtained in...

Durability of High Performance Concrete
The freeze-thaw durability and the resistance to chloride penetration of high performance concrete (HPC) developed for highway applications were investigated. This paper summarizes the...

SHRP Deformation Test?Asphalt Mix Tests and Analysis Systems
From analyses of existing information on the permanent-deformation characteristics of asphalt/binder-aggregate mixes, as well as the development of permanent deformation in pavement structures,...

 

 

 

 